2017年3月9日星期四

How to deal with the malfunction of the amusement equipment

childrens indoor play equipment in the running time will always fail, then the failure of how to solve it? One can not start 1. Electric control cabinet and line failure. Can not start the first to check whether the cabinet is working, first check the electric control cabinet power indicator light is not lit, the light is on the case that the power supply access control cabinet line is no problem, the light does not light first check Power supply access control cabinet line there is no problem of disconnection and short circuit, if there is to re-connect or replace the line. No problem then open the electronic control cabinet to check whether the relay knife closed, insurance, whether the phenomenon of fusing, if closed and replaced. If the fault persists, check whether the wiring of the electric control cabinet to access the conductive ring is broken (the position of the conductive ring is in the center of the rotor), the circuit of the conductive ring to the motor is disconnected, if it is re-connected or replaced line. Check the conductive ring and carbon brush contact with the Department of dust and poor contact with the situation, if you can use a screwdriver to press a few times. 2. motor failure. Electric control cabinet and the line did not fail or troubleshooting still can not check the motor is not a fault, the motor belt pulley on the removal of the electric control cabinet to start the boot button, and then see the motor has no work, if there is no work Is the motor is damaged and needs to be replaced. Second, difficult to start 1. Bearing too tight. The occurrence of such a failure generally occurs in the new situation of the majority of the horse can be used to adjust the wrench can be moderate, the other can add lubricants better. 2. Voltage is unstable or too low. Many devices are difficult to start or can not start because of voltage instability or too low, mainly due to the nearby voltage load caused by excessive, this phenomenon is particularly evident in the summer. Check the way is to press the electric control cabinet start button to observe whether the voltage meter is normal. The solution is to replace the larger square of the power cord or replace the line access point. The most direct but not effective way is to press the electric control cabinet start button, and then find two people to promote the broader market to see if it can run normally. 3. V-belt loose. If the V-belt is loose, you can adjust the distance between the motor and the pulley or replace the new V-belt with the same type. Third, the jitter and noise is too large Jitter and noise is too large problem is because the market is not smooth operation caused by the tire can check whether the leak or air pressure is not enough, leak, then to replace or repair, the pressure is not enough Can be inflated tire, the general three semi-pressure can be. Second, due to transmission parts and bearing friction increases, you can add lubricants.

没有评论:

发表评论